TTU-GLA-070/MP industry temperature sensors (RTD), with analogue or digital output

Iskanje

Šifra: TTU-GLA-070/MP


Po naročilu. Pošljite povpraševanje.

Delivery time: 3 working days or urgent

  • Number of sensors: 1 or 2
  • measuring element: Pt100 or Pt 1000
  • output 4 … 20 mA or 0 … 10 V
  • Accuracy class: A or A+
  • Sensor binding: 2, 3 or 4 water
  • Installation length: x (mm)
  • length of the protective neck: 55 mm or x
  • Process connection: G 1/2” or x
  • diameter of the protective tube: 6 mm or x
  • x: select as desired; bold: standard version
  • INOR measuring transducer, output 4 … 20 mA or 0 … 10 V
rotronicELPRO


Področja:

Description

The TTU-GLA-070/MP industry temperature sensor (RTD) has a connection head and a process connector on the protective neck.

Because it is in a protective housing(Thermowell with measuring insert) and has a built-in measuring transducer, it is suitable for temperature measurement in industrial processes (liquids, gases, vacuum) where you need, for example: a Pt100 converted to 4 … 20 mA, temperature linear.

 


Measuring transducers
can perform other tasks, such as:

  • cycle counting
  • control sensor error (sensor error )
  • system error
  • correction of sensor error
  • correction of system error
  • galvanic isolation
  • 50 point linearisation
  • HART
  • use in Ex zones
  • working in demanding work areas

… functions depend on the choice of converter model

 

The measuring range and output of the transducer are user-configurable with the INOR software.

  • new series of inverters allow configuration or setup with smartphones with NFC® (Near-field communication) reader and Bluetooth®

 

A reinforced protective neck above the process connection for increased structural strength

  • the sensor head rotates

 

Special features and advantages of the TTU-GLA-070/MP

  • fast response due to installation in an existing housing or directly into the media
  • Reinforced protective neck – structural strength
  • spare measuring insert, hose protection (ETFE, ECTFE, PTFE), Ex, ON SITE CAL
  • accessories: swivel head, see coding table

 

Main features

  • Temperature range/output: -200 to 850 °C; most commonly -50 to 450 °C
  • standard in class A (±0.15 °C at 0 °C according to EN 60751 : 2008)
  • with analogue or digital output for TTU-GLA-070/MP version
  • recommended min installation length (depth) is 10 times the pipe outer diameter
  • Output: 4 … 20 mA or 0-10 V, temperature linear

 

Use

  • industry standard, immersion measurements

 

Choice of implementation

Select the desired design from the code list in the Documentation tab and call 02 62 96 720 orwrite to us on the Enquiry form and let us help you make your choice.

We have also prepared a set of very common versions for you: the TTU-GLA-070, which is also available in our online shop:

 

The dimpled tip is chosen for faster air measurements (ventilation) and the tapered tip for fast measurements of other media.

The sensor can also be available in Ex version or in combination without transducer, see
TTU-GLA-070
.

 

Thermowell version

Temperature sensors with protective housing or thermowell versions have a replaceable measuring cartridge inside for easy replacement or calibration without interrupting the process.

The protective neck protects the connection head and the converter from higher process temperatures.

The thermowell itself can be further protected with PTFE or similar protection for aggressive media.

  • all external parts are welded to the housing

 

Benefits of industry versions

High accuracy, long life and stability. All this is achieved through strict quality control of materials and processes.

 

Protection for aggressive media

The process connection can be protected with PTFE protection for aggressive media, and other parts of the housing if required. Here you can see an example.

 

TTU-GLA-070/MP in ON SITE and EX versions

For calibration directly in the production process, we produce the TTU-GLA-070 in ON SITE version.

For use in EX rooms/areas, we manufacture/supply the ATEX-certified TTU-GLA-070.

 

Recommendation

We recommend a mounting length of at least ten times (10x) the pipe diameter, shorter lengths have a negative impact on the accuracy of the measurement.

 

Additional services and equipment

 

Custom temperature sensor and order

All temperature sensors can be made to your specifications and requirements. Together with our experts, we design the best solution for you.

We are no strangers to special and unusual challenges. The most common designs are presented on the website, but in practice, production is mainly made to order.

 

Call or email us and we will help you determine/choose the most suitable implementation for you based on your process requirements.

Standard delivery time is up to 5 working days, urgent deliveries within the deadline are possible
24 h
.

 

How to order a sensor

From the Inquiry box, please send your requirements in which you write down the operating temperature, the desired dimensions and the purpose of use.

Don’t forget your phone number and email address. We will call you and/or send you a quotation to confirm it before implementation.

Find out more about making bespoke temperature sensors here.

 

Guaranteed

24 h support
– 100% output control
– long life in a circular economy system
– product repairability
service and
calibrations

 

ELPRO Adhesive temperature sensors have a 5-year manufacturer’s warranty and are made in Slovenia. INOR transducers come with a 5-year manufacturer’s warranty and are made in Sweden.

Other designations: TTU-GLA-070/MP, TTU-GLA_070-MP, TTU GLA 070/MP, TTU-GLA_070-MP, TTU-GLA

 

You are invited to read

Total cost of ownership – ELPRO LEPENIK & CO. d.o.o.

Povpraševanje

    You may also like…