Leckstar 101/S relay for JOLA leak detectors

Iskanje

Šifra: Leckstar 101/S


Ni v zalogi. Pošljite povpraševanje.

Delivery time: okvirno 2 tedna

  • supply voltage: 230 V AC; on request: 240, 115, 24 V AC or 24, 12 V DC
  • power supply: approx. 3 VA
  • switching indicator: via 3 LED lights
  • protection class: IP20
  • temperature range: -20 °C to +60 °C
za merjenje nivoja tekočin, detekcija uhajanja


Področja:

Description

The Leckstar 101/S relay for JOLA leak detectors is designed for limit level signalling. They shall be installed in a control cabinet or other suitable protective enclosure. The switches are suitable for use in clean environments.

  • with cable disconnect control and switchable self-hold
  • with separately routed output for cable break monitoring
  • for connection of 1 conductive electrode with cable break monitoring unit Z10
  • with 2 potential-free interrupting (NC) contacts at the output

Electronic relay for DIN rail mounting or surface mounting, with connection terminals at the top and 3 integrated LEDs to indicate operating conditions

Self-restraint:

  • If the Self-hold switch is activated, an alarm is stored. The relay continues to signal the alarm even if the cause of the alarm (e.g. presence of water or cable break) is no longer present – in other words, if the sensor is dry again or if the line is in contact. The alarm is acknowledged by switching off the self-hold switch.
  • If the self-hold switch is not switched on, the alarm will not be maintained when the cause of the alarm is eliminated, but will be interrupted.

Before use, we recommend viewing the attached pdf documents under the Documentation tab.

 

Features of Leckstar 101/S

  • supply voltage: 230 V AC; on request: 240, 115, 24 V AC or 24, 12 V DC
  • Power supply: approx. 3 VA
  • electrode circuit. 2 terminals (under safety extra-low voltage SELV) operating on 1 output relay with switching self-test
  • no-load voltage: 18 Veff 10 Hz (safety low voltage SELV)
  • short-circuit current: max. 0.5 mAeff
  • response sensitivity: approx. 30 kW or approximately 33 µS (electrical conductivity)
  • first power circuit: 1 single-pole potential-free (NC) contact based on the quiescent current principle for signalling a leakage or cable break
  • second power circuit: 1 single-pole contact without potential (NC) based on the quiescent current principle for additional signalling in the event of a cable break
  • switching indicator: via 3 LED lights
  • switching voltage: max. AC 250 V
  • switching current: max. AC 4 A
  • switching power: max. 500 VA
  • housing: insulating material, 75 x 55 x 110 mm
  • connection: iterminals on the housing
  • protection class: IP20
  • mounting: on 35 mm DIN rail or fixing via 2 drill holes
  • orientation of installation: any
  • temperature range: -20 °C to +60 °C
  • max. Connecting cable length: 1,000 m between the electrode relay and the Z10 cable break monitoring unit