  • Design: 1 control electrode and 1 earth electrode
  • housing: PP (on request: PVDF or PTFE), 28 mm Ø x approx. 130 mm
  • electrical connection: connection cable 2×0.75 length:2m
  • temperature range: -20 °C to +60 °C (higher temperatures on request)
  • cable break monitoring: with integrated Z10 cable break monitoring unit
za merjenje nivoja tekočin, detekcija uhajanja


Področja:

Description

The EHW 2-Z10 JOLA hanging electrode is designed to signal the presence of an electrically conductive liquid caused by, for example, a burst pipe, via a connected bar electrode relay.

Suspension conductive electrodes are designed to signal the presence of an electrically conductive fluid caused by, for example, a burst hose, via a connected conductive electrode relay.

Suspension conductive electrodes must only be used in normally dry environments. They must be installed in a hanging mode from above, so that the electrode rods are only slightly above the floor to be controlled.

The conductive spring electrodes are equipped with two sensitive elements in the form of two electrode rods: 1 control electrode and 1 earth electrode. If the electrode rods come into contact with an electrically conductive liquid (e.g. water, acid, etc.), electrical contact is established and an alarm signal is triggered.

Before use, we recommend viewing the attached pdf documents under the Documentation tab.

EHW 2-Z10 features

  • Design: 1 control electrode and 1 earth electrode
  • Sensitive element: 2 electrode plates in 316 Ti stainless steel
  • housing: PP (on request: PVDF or PTFE), 28 mm Ø x approx. 130 mm
  • electrical connection: connection cable 2×0.75, length:2m, made of CM or PTFE
  • temperature range: -20 °C to +60 °C (higher temperatures on request)
  • cable break monitoring: with integrated Z10 cable break monitoring unit
  • Classification:
    • One or more EHW.-4 can be connected in parallel between EHW.-Z10 and one of these relays.
    • Leckstar 101 or Leckstar 101 / S: en EHW.-Z10
    • Leckstar 171/1 or Leckstar 171/2: one EHW.-Z10
    • Leckstar 155: max. five EHW.-Z10
  • length of connecting cable: 1,000 m between the electrode relay and the rear electrode
  • installation accessories: on request, filler nipples, enclosures with integrated filler nipples and flanges with filler nipples