EBI 12-T490 data logger for measurement in EBRO steam steriliser
Po naročilu. Pošljite povpraševanje.
Delivery time: approximately 2-3 weeks
- measuring range: -20 … + 150 °C
- memory: 2 x 50.160
- two sensors: fi 1.2 mm, radial (side) connection
Standards and directives
- (EC) 1935/2004 – materials and articles that come into contact with food
- ISO 17665 – Sterilisation of health care products
- 2014/53/EU – Radio Equipment Directive – RED
Description
The EBI 12-T490 is a validation data logger for process validation in a steam sterilizer and batch control in production.
The Logger has quite flexible cable probes that allow precise positioning of the sensor. Very thin temperature sensors with a diameter of 1.2 mm at the tip of the sensor allow very fast response times.
When using the recorder in a WD, it is strongly recommended to attach the probes with silicone cable ties. The EBI 12-T490 is ideal for measuring temperature and humidity in sterilisation chambers, especially for accurate monitoring of the sterilisation process in cavities and other confined spaces.
Who is the EBI 12-T490 suitable for?
- Healthcare: can be used in hospitals and clinics to monitor autoclave sterilisation processes, recording and documenting temperature and time data.
- Pharmaceutical industry: can be used in pharmaceutical companies where it is necessary to monitor sterilisation processes and temperature conditions in the production of medicines.
- Food industry: can also be used in the food industry to monitor sterilisation processes and ensure food safety.
- Research facilities: can be used in research facilities to monitor temperature conditions in various experimental environments.
In general, the EBI 12-T490 is suitable for anyone who needs accurate monitoring of temperature and time in sterilisation processes, including autoclaves and other types of sterilisers.
Technical specifications
- operating temperature: -20 °C … +150 °C
- measuring range: -20 °C … +150 °C
- accuracy:
- ±0.2 °C (-20 °C … 0 °C)
- ±0.1 °C (0 °C … +120 °C)
- ±0.05 °C (+120 °C … +140 °C)
- ±0.1 °C (+140 °C … +150 °C)
- resolution: 0.01 °C
- two sensors: fi 1.2 mm, radial (side) connection
- data memory: 2 x 50,160 measurements
- Sensor: Pt1000, class A
- measuring interval: 250 ms … 24 hours
- real-time data transmission: yes
- storage temperature: -20 °C … +70 °C
- measurement methods:
- infinite measurement
- measured at the start time
- start immediately to the end of memory
- start/stop of measurement
- battery: lithium, 3.6 V, user replaceable
- dimensions: (Ø x H) 48 mm x 24 mm
- weight: approx. 90 g
- Housing material: stainless steel 316 L / PEEK
- Protection class: IP68
- factory calibration certificate: 0 °C, +60 °C and +134 °C
Standards and directives
- (EC) 1935/2004 – materials and articles that come into contact with food
- ISO 17665 – Sterilisation of health care products
- 2014/53/EU – Radio Equipment Directive – RED
Software
- Set SI 2150 – Winlog.pro
- Set SI 1200 – Winlog.pro
- Set SI 3300 – Winlog.med
- Set SI 2110 – Winlog.med
- Set SI 11o0 – Winlog.med
Video
Read the articles:
- THE DIFFERENCE BETWEEN A HYDROMETER AND A HYGROMETER
- Measuring room temperature and humidity
- Loggers – process monitoring (cold chain, HACCP, transport, storage, process control…)
- Process monitoring, routine controls and validations
- Quality of EBRO loggers
- Data loggers for process validation
Other designations: EBI12-T490, EBI12T490, EBI-12-T490
Povpraševanje
You may also like…
For your victories, with our solutions. Call us:
Contact us.
Call us:
+386 (0)2 62 96 720
Email us:
[email protected]