EBI 12-TP222 data logger for measurement in EBRO autoclaves

Iskanje

Šifra: EBI 12-TP222


Po naročilu. Pošljite povpraševanje.

Delivery time: approximately 2-3 weeks

  • measuring range : 0 … +150 °C, 1 … 4.000 mbar
  • Data storage: 2 x 33,440 measurements
  • Sensor: external Pt1000, pressure sensor (combined, interchangeable)

Standards and directives

  • (EC) 1935/2004 – materials and articles that come into contact with food
  • ISO 17665 – Sterilisation of health care products
  • ISO 15883 – Washing and disinfecting machines
  • 2014/53/EU – Radio Equipment Directive – RED

Description

The EBI 12-TP222 is an advanced data logger designed specifically for measuring autoclave temperature and pressure. It is used for process control and validation in steam sterilisers and washer-disinfectors.

It is equipped with a temperature and pressure sensor that ensures extremely accurate measurements and ensures that sterilisation procedures are carried out correctly and reliably. The device is simple to use and can be quickly and easily installed in the autoclave. You can use the included software to monitor the data or simply download the data to Excel.

The Logger features flexible metal probes. The very thin 1.5 mm diameter bendable axial temperature sensors at the tip of the sensor allow very fast response times. With this recorder and the AL 126 endoscope flow control adapter, it is easy to perform regular routine checks in the RDG-E.

 

Who is the EBI 12-TP222 suitable for?

  • Clinical laboratories and dental practices that sterilise medical instruments and tools in autoclaves.
  • Pharmaceutical companies that manufacture sterile medical devices and medicines and must ensure that sterilisation procedures are closely monitored.
  • Veterinary clinics and hospitals that have to sterilise medical equipment and devices for use on animals.
  • Research institutions that carry out sterilisation research and need to monitor sterilisation procedures.
  • Quality and validation professionals looking for a reliable and accurate tool to monitor autoclave sterilisation processes.
  • All sterilisation organisations that need reliable and accurate monitoring of autoclave sterilisation processes.
  • All those who want to ensure that the sterilisation procedures in their autoclaves are safe and effective.

 

Technical specifications

  • operating temperature: 0 °C … +150 °C
  • measuring range : 0 … +150 °C, 1 … 4.000 mbar
  • temperature accuracy:
    • ±0.1 °C (0 … +120 °C)
    • ±0.05 °C (+120 … +140 °C)
    • ±0.1 °C (+140 … +150 °C)
  • pressure accuracy:
    • ± 15 mbar (1 mbar … 49 mbar)
    • ± 10 mbar (50 mbar … 150 mbar)
    • ± 15 mbar (151 mbar … 2.049 mbar)
      ± 10 mbar (2.050 mbar … 2.250 mbar)
    • ± 15 mbar (2.241 mbar … 2.999 mbar)
    • ± 10 mbar (3,000 mbar … 3,250 mbar)
    • ± 15 mbar (3.251 mbar … 3.499 mbar)
    • ± 20 mbar (3,500 mbar … 4,000 mbar)
  • resolution: 0.01 °C, 1 mbar
  • data storage: 2x 33,400 measurements
  • Sensor: Pt1000, Class A
  • Pressure sensor: piezoresistive
  • sample interval: 250 ms … 24 h
  • how to measure:
    • infinite
    • start/stop
    • measurements with a fixed start
    • Initial start and measurement until memory space is full
  • storage temperature: -20 °C … +70 °C
  • battery: lithium, 3.6 V, replaceable
  • Dimensions: 48 mm x 24 mm (depending on model)
  • weight: approx. 90 g
  • housing: 316L stainless steel/PEEK
  • Protection class: IP68
  • Factory calibration certificate:
    • 0 °C, +60 °C and +134 °C
    • 100 mbar and 3,100 mbar (at +25 °C)
    • 3,100 mbar (at +134 °C)

 

Standards and directives

  • (EC) 1935/2004 – materials and articles that come into contact with food
  • ISO 17665 – Sterilisation of health care products
  • ISO 15883 – Washing and disinfecting machines
  • 2014/53/EU – Radio Equipment Directive – RED

 

Software

 