EBI 11-P100 mini data logger for pressure validation EBRO

Iskanje

Šifra: EBI 11-P100


Po naročilu. Pošljite povpraševanje.

  • the measuring area:
    • temperature: 0 °C … +150 °C
    • pressure: 1 mbar … 10,000 mbar
  • Temperature accuracy: ±0.1 °C (0 °C … +150 °C)
  • pressure accuracy:
    • ±15 mbar (0 … 4.000 mbar)
    • ±20 mbar (4.000 mbar … 10.000 mbar)
  • Resolution:
    • temperature: 0.01 °C
    • pressure: 1 mbar

Description

The EBI 11-P100 mini data logger for pressure validation is designed to monitor temperature and relative humidity in a variety of applications such as drug storage, food, laboratory applications and transport.

This compact logger boasts a large measuring range for temperature(0°C to +150°C) and pressure(1 mbar … 10,000 mbar). Thanks to its robust design and water resistance(IP68), it can be used in a wide range of environmental conditions.

The EBI 11-P100 is made of high-quality materials, ensuring its robustness and durability. Due to its compact size, it can be used to monitor pressure and temperature in hard-to-reach places.

The data logger has a simple interface that makes it easy to set up and manage. Measurement data can be stored on the device or transferred to a computer via USB.

It is ideal for use in environments where accurate pressure and temperature monitoring is required, such as drug manufacturing, transport and logistics companies and the chemical industry. With its ease of use, robust design and accurate measurements, the EBI 11-P100 is the ideal choice for many applications requiring pressure and temperature monitoring.

 

Who is the EBI 11-P100 suitable for?

  • Production plants that carry out manufacturing processes that require precise pressure control. The EBI 11-P100 is suitable in this case for collecting pressure data and ensuring compliance with regulations.
  • Pharmaceutical companies can use EBI 11-P100 to validate processes involving pressure and ensure compliance with strict pharmaceutical manufacturing regulations.
  • Laboratories can use the EBI 11-P100 for pressure monitoring in sterile environments and clean rooms, where accuracy and reliability are critical.
  • Scientists and researchers can use the EBI 11-P100 to monitor pressure in research processes where accuracy is important.
  • Medical device manufacturers can use EBI 11-P100 to ensure compliance with medical device manufacturing regulations that require accurate pressure monitoring.
  • Food manufacturers can use the EBI 11-P100 to monitor atmospheric pressure in warehouses and production facilities where accuracy is critical to ensure food quality and freshness.

 

Technical specifications

  • operating temperature: 0 °C … +150 °C
  • the measuring area:
    • temperature: 0 °C … +150 °C
    • pressure: 1 mbar … 10,000 mbar
  • Temperature accuracy: ±0.1 °C (0 °C … +150 °C)
  • pressure accuracy:
    • ±15 mbar (0 … 4.000 mbar)
    • ±20 mbar (4.000 mbar … 10.000 mbar)
  • Resolution:
    • temperature: 0.01 °C
    • pressure: 1 mbar
  • data memory: 2 x 7,500 measurements
  • sensor: pt1000, class A
  • measuring interval: 1 s … 24 hours
  • storage temperature: -20 °C … +70 °C
  • measurement methods:
    • infinite measurement
    • measure at the start time
    • instant start to the end of memory
    • start/stop measurement
  • battery: lithium, 2x BR1225A, 3V, user replaceable
  • Dimensions: (Ø x H) 16.5 mm x 48 mm
  • weight: 45 g
  • Housing material: 316 TI stainless steel
  • Protection class: IP68
  • factory calibration certificate:
    • 0 °C, +60 °C and +134 °C
    • 100 mbar, 3,100 mbar, 6,000 at +25 °C
    • 3,100 mbar at +134 °C

 

Software (extra charge)

Choose from the following sets:

 

Standards and Directives:

  • ISO 17665 – Sterilisation of health care products – moist heat
  • ISO 15883 – Washing and disinfecting machines
  • (EC) 1935/2004 – materials and articles that come into contact with food
  • 2014/30/EU – Electromagnetic compatibility of equipment

 

Video

 

Read the articles:

 

Other designations: EBI11-P100, EBI-11-P100, EBI_11-P100

Povpraševanje