EBI 12-TP451 data logger for EBRO benchtop autoclaves

Iskanje

Šifra: EBI 12-TP451


Po naročilu. Pošljite povpraševanje.

Delivery time: okvirno 2 tedna

  • measuring range: 0 °C … +150 °C, 1 … 4,000 mbar
  • Temperature accuracy: ±0.1 °C, ±0.05 °C, ±0.1 °C
  • resolution: 0.01 °C, 1 mbar
  • data memory: 4 x 20.064 measurements

Standards and Directives:

  • ISO 17665 – Sterilisation of medical products
  • 2014/53/EU – Radio Equipment Directive RED
  • (EC) 1935/2004 – materials and articles that come into contact with food

Description

The EBI 12-TP451 data logger for EBRO benchtop autoclaves is a validation logger for process control and validation in small sterilizers.

The Logger has 3 temperature sensors and a pressure sensor to provide accurate data on the sterilisation process. The sensors are highly flexible, allowing precise positioning in the steriliser.

The sensors have very thin tips (1.2 mm diameter), which gives them a faster response time. If the logger is used in a washer-disinfector, it is recommended to attach it with silicone cable ties.

 

Who is the EBI 12-TP451 suitable for?

  • validation of thermal processes with steam sterilisers,
  • measurement in small sterilisers,
  • use in washing and disinfection processes,
  • for use in medical and pharmaceutical processes, where precise positioning of sensors is crucial,
  • applications where very fast sensor response times are needed.

 

Technical specifications

  • operating temperature: 0 °C … +150 °C
  • measuring range: 0 °C … +150 °C, 1 … 4,000 mbar
  • temperature accuracy:
    • ±0.1 °C (0 °C … +120 °C)
    • ±0.05 °C (+120 °C … +140 °C)
    • ±0.1 °C (+140 °C … +150 °C)
  • pressure accuracy:
    • ±15 mbar (1 mbar … 49 mbar)
    • ±10 mbar (50 mbar … 150 mbar)
    • ±15 mbar (151 mbar … 2.049 mbar)
    • ±10 mbar (2.050 mbar … 2.250 mbar)
    • ±15 mbar (2.241 mbar … 2.999 mbar)
    • ±10 mbar (3,000 mbar … 3,250 mbar)
    • ±15 mbar (3.251 mbar … 3.499 mbar)
    • ±20 mbar (3,500 mbar … 4,000 mbar)
  • resolution: 0.01 °C, 1 mbar
  • data memory: 4 x 20.064 measurements
  • sensor: pt1000, class A
  • pressure sensor: piezoresistive pressure sensor
  • measuring interval: 250 ms … 24 hours
  • Real-time data transmission: yes
  • storage temperature: -20 °C … +70 °C
  • measurement methods:
    • infinite measurement
    • measurement at start time
    • instant start to the end of memory
    • start/stop measurement
  • battery: lithium, 3.6 V, user replaceable
  • Dimensions: (Ø x H) 48 mm x 24 mm
  • weight: approx. 90 g
  • Housing material: 316 L stainless steel / PEEK
  • Protection class: IP68
  • factory calibration certificate:
    • 0 °C, +60 °C and +134 °C
    • 100 mbar and 3,100 mbar (at +25 °C)
    • 3,100 mbar (at +134 °C)

 

Standards and Directives:

  • ISO 17665 – Sterilisation of medical products
  • 2014/53/EU – Radio Equipment Directive RED
  • (EC) 1935/2004 – materials and articles that come into contact with food

 

Software:

 