EBI 12-TP231 validation data logger for steam sterilisers and WD EBROs
Po naročilu. Pošljite povpraševanje.
Delivery time: okvirno 2 tedna
- resolution: 0.01 °C, 1 mbar
- data memory: 4 x 33,440 measurements
- sensor: pt1000, class A
- pressure sensor: piezoresistive pressure sensor
Description
The EBI 12-TP231 is a validation data logger suitable for measuring temperature and pressure in thermal treatment processes in steam sterilizers and WDs. It is an extremely accurate and easy-to-use data logger. The data logger features an external rigid axial temperature sensor with a diameter of 1.95 mm.
In addition, it can be used for routine control in RUMED. The EBI 12-TP231 allows accurate monitoring of temperature and pressure changes in sterilisers and WDs, ensuring the safety and efficiency of medical device reprocessing procedures.
Who is the EBI 12-TP231 suitable for?
- Users who perform thermal process testing with steam sterilisers and WDs and need reliable temperature and pressure data.
- Healthcare facilities, laboratories, pharmaceutical companies and other industries that have to comply with strict standards for sterilising and dealing with infectious diseases.
- Technical experts and engineers who maintain sterilisation equipment and carry out validation tests.
- Users who need easy and reliable monitoring of the sterilisation process for routine control in RUMED.
The EBI 12-TP231 is designed for use in a variety of environments where reliable monitoring of sterilisation processes is important.
Technical specifications
- operating temperature: 0 °C … +150 °C
- measuring range: 0 °C … +150 °C, 1 … 4,000 mbar
- temperature accuracy:
- ±0.1 °C (0 °C … +120 °C)
- ±0.05 °C (+120 °C … +140 °C)
- ±0.1 °C (+140 °C … +150 °C)
- pressure accuracy:
- ±15 mbar (1 mbar … 49 mbar)
- ±10 mbar (50 mbar … 150 mbar)
- ±15 mbar (151 mbar … 2.049 mbar)
- ±10 mbar (2.050 mbar … 2.250 mbar)
- ±15 mbar (2.241 mbar … 2.999 mbar)
- ±10 mbar (3,000 mbar … 3,250 mbar)
- ±15 mbar (3.251 mbar … 3.499 mbar)
- ±20 mbar (3,500 mbar … 4,000 mbar)
- resolution: 0.01 °C, 1 mbar
- data memory: 4 x 33,440 measurements
- sensor: pt1000, class A
- pressure sensor: piezoresistive pressure sensor
- measuring interval: 250 ms … 24 hours
- Real-time data transmission: yes
- storage temperature: -20 °C … +70 °C
- measurement methods:
- infinite measurement
- measurement at start time
- instant start to the end of memory
- start/stop measurement
- battery: lithium, 3.6 V, user replaceable
- Dimensions: (Ø x H) 48 mm x 24 mm
- weight: approx. 90 g
- Housing material: 316 L stainless steel / PEEK
- Protection class: IP68
- factory calibration certificate:
- 0 °C, +60 °C and +134 °C
- 100 mbar and 3,100 mbar (at +25 °C)
- 3,100 mbar (at +134 °C)
Standards and Directives:
- ISO 17665 – Sterilisation of medical products
- 2014/53/EU – Radio Equipment Directive RED
- (EC) 1935/2004 – materials and articles that come into contact with food
- ISO 15883 – Disinfectors For Washing Machines
Software:
- Set SI 2150 – Winlog.pro
- Set SI 1200 – Winlog.pro
- Set SI 2110 – Winlog.med
- Set SI 2100 – Winlog.med
- Set SI 3200 – Winlog.validation
Video
You are invited to read the articles
- THE DIFFERENCE BETWEEN A HYDROMETER AND A HYGROMETER
- Measuring room temperature and humidity
- Loggers – process monitoring (cold chain, HACCP, transport, storage, process control…)
- Process monitoring, routine controls and validations
- Quality of EBRO loggers
- Data loggers for process validation
Other designations: EBI-12-TP231, EBI 12 TP231, EBI12TP231