DPGS43HP.160 differential pressure gauge with switchable contacts WIKA

Iskanje

Šifra: MAN-DPGS43HP.160


Po naročilu. Pošljite povpraševanje.

  • differential pressure measurement is from 0 … 60 mbar
  • switch contact instruments for PLC applications
  • measuring the damping of cell fluid against rapid pressure changes
  • instruments with inductive contacts for use in hazardous areas
  • high working pressure (static pressure) and high overload protection, optionally up to 40, 100, 250 or 400 bar


Področja:

,

Description

The DPGS43HP.160 differential pressure gauge with switchable contacts from WIKA is used for monitoring differential pressures, the instrument allows switching and display.

Where process pressure needs to be specified locally and circuits need to be switched at the same time, the DPGS43HP.160 GAUGE switch finds its application.

Switch contacts (electrical alarm contacts) form or break circuits depending on the position of the pointer of the indicating instruments. The switch contacts are adjustable over the full range of the dial (see DIN 16085) and are located mainly under the dial, but also partly on the top of the dial. The instrument pointer (actual value indicator) moves freely over the full scale range, independent of the setting.
You can adjust the set cursor using the removable adjustment key in the window.

You can also set multiple contacts to a single set point. The contact is triggered when the actual value pointer moves above or below the desired set point.

The pressure gauge is manufactured in accordance with DIN 16085 and meets all the requirements of the relevant standards (EN 837-3) and regulations for the on-site indication of the working pressure of pressure vessels.
Magnetic contacts, reed switches, inductive contacts and electronic contacts are available as switch contacts. Inductive contacts can be used in hazardous areas. Electronic contacts and reed switches can be used to trigger programmable logic controllers (PLCs).

 

Features of DPGS43HP.160

  • Implementation:

    • Maximum overload protection on both sides, nominal pressure PN 40, 100, 250 or 400, the filling fluid of the load cell system acts as a screen damper.
    • Overload resistance according to EN 837-3.
  • Nominal size in mm: 160
  • Accuracy class 1.6
  • Option:
    • 1.0 on request, (Monel version: 2.5)
  • The scale includes:

    • Instruments with PN 40 and 100:
      • 0… 60 mbar to 0… 160 mbar (measuring cell □ 140)
      • 0… 0.25 bar to 0… 40 bar (measuring cell □ 82)
    • Instruments with PN 250:
      • 0… 60 mbar to 0… 250 mbar (measuring cell □ 140)
      • 0… 0.4 bar to 0… 40 bar (measuring cell □ 82)
    • Instruments with PN 400:
      • 0… 0.4 bar to 0… 40 bar (measuring cell □ 86)
      • Dimensions of the measuring cell, see technical data sheet
      • other units available (e.g. psi, kPa)
      • or any other equivalent pressure and vacuum ranges
  • Scale:

    • Single scale
    • Option:
      • Double Rock
      • Scaling (e.g. linear pressure or square root increase)
  • Zero point setting: using the setting device
  • Pressure limit:

    • Constant value of the overall scale
    • Niha 0.9 x total scale value
    • Follow the recommendations for the use of mechanical pressure measurement systems according to EN 837-2
  • Safety overpressure and max. working pressure (static pressure): both sides max. 40, 100, 250 or 400 bar
  • Connection point:

    • Bottom bracket (radial)
    • Option:
      • Rear carrier
      • Link at 12. Hours
  • Process link:

    • G ½ B female
    • G ½ B male
    • ½ NPT male
    • Differential process link according to EN 61518
    • Other procedural links via female or male threads on request
  • Allowable temperature:

    • Medium -20 °C … +100 °C
    • Option:
      • Medium temperature > 100°C on request
    • Environment -20 °C … +60 °C
    • Option:
      • Ambient temperature -40 °C … +60 °C (silicone oil filling)
  • Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C):
    • max. ± 0.5 % / 10 K of the total scale value
  • Charging the housing

    • Without
    • Option:
      • By filling the casing
  • Vapourising the media chambers:

    • PN 40 and 100: For range ≤ 0.16 bar (option for scale range ≥ 0.25 bar)
    • Instruments with PN 250 and 400: Standard for scale range ≤ 0.25 bar (option for scale range ≥ 0.4 bar)
    • Option:
      • Media chamber venting for volumes ≥ 0.25 bar or ≥ 0.4 bar
  • System for filling the measuring cell liquid:

    • Silicone oil
    • Option:
      • Measurement of cell filling with a specific medium, e.g. for use in oxygen applications
      • Others on request
  • Wet materials:

    • Measuring flanges with a process connector:
      • 316L stainless steel
    • Flange connection bolts
      • PN 40/100: stainless steel
      • PN 250/400: corrosion-protected steel
    • Pressure elements
      • ≤ 0.25 bar: stainless steel 1,4571
      • > 0.25 bar: NiCr alloy (Inconel)
    • Measuring cell:
      • Chrome-plated steel
    • Vapourising the media chambers:
      • 316L stainless steel
    • Seals
      • FPM / FKM
  • Non-wetted materials

    • Housing, stroke, stainless steel bayonet ring
    • Aluminium dial, white, black
    • Index
      • Aluminium, black
    • Window
      • Laminated safety glass
    • Ingress protection to IEC/EN 60529: IP54
      • Option:
      • IP65 with liquid filling
    • Installation According to the attached symbols: ⊕ high pressure, ⊖ low pressure
    • Installation:

      • Rigid measuring lines
      • Drilled mounting holes on the back of the measuring cell
      • Option:
        • Flange for fixing the panel
        • Wall or pipe mounting bracket
    • Electrical connection

      • Cable socket PA 6, black
      • To insulation group VDE 0110 C/250 V
      • Cable gland M20 x 1.5
      • Relieving strains
      • 6 screw terminals + PE for conductor cross section 2.5 mm²
      • For dimensions, see technical data sheet
      • others on request

For more features and additional options of the DPGS43HP.160, we recommend viewing the attached .pdf documents under the Documentation section.

 

Areas of use, applications

Using DPGS43HP.160:

  • process control and regulation
  • plant control and switching of electrical circuits
  • pump monitoring and control, filter monitoring, level measurement on closed tanks
  • easy-to-read, analogue on-site display that requires no external power supply
  • for measuring locations with high differential pressure overload and/or high operating pressures (static pressures), also in aggressive environments

 

ELPRO designation: MAN-DPGS43HP.160