762.14 WIKA differential industrial pressure gauge

Iskanje

Šifra: MAN-762.14


Po naročilu. Pošljite povpraševanje.

  • Model 762.14: Version with special materials (Monel, Hastelloy)
  • high working pressure (static pressure) and high overload safety, optional
  • the transmission fluid in the measuring chamber dampens the indicator in the event of large changes in pressure velocity
  • differential pressure measurement is from -1 … + 30 bar [-14.5 … +435 psi] to 0 … 40 bar [0 … 580 psi]


Področja:

, ,

Description

The 762.14 WIKA industrial differential pressure gauge with high load safety up to 40, 100 or 400 bar is used for measuring pressure differentials of gaseous and liquid media.

These differential pressure gauges are made of corrosion-resistant stainless steel. High safety over pressure is achieved by the metal construction and the tight-fitting pressure measuring diaphragm.

With its high-quality stainless steel construction and robust design, this pressure gauge is adapted to chemical and process engineering.

The wetted parts of these instruments are also available in special materials such as Monel or Hastelloy.

Scale ranges from 0 … 60 mbar to 0 … 40 bar provide the measuring ranges required for a wide variety of applications.

 

Features 762.14

  • Design:

    differential pressure gauge to DIN 16003, maximum overload protection on both sides, nominal values PN 40, 100, 250 or 400. The transfer fluid in the measuring chamber dampens the indicator in the event of large changes in the pressure level.

  • Nominal size in mm: 100, 160
  • accuracy class: 2.5
  • the scale range:

    • Instruments with PN 40 and 100:
      • 0… 60 mbar to 0… 160 mbar (measuring chamber □ 140)
      • 0… 0.25 bar to 0… 40 bar (measuring chamber □ 82)
    • Instruments with PN 250:
      • 0… 60 mbar to 0… 250 mbar (measuring chamber □ 140)
      • 0… 0.4 bar to 0… 40 bar (measuring chamber □ 82)
    • Instruments with PN 400:
      • 0… 0.4 bar to 0… 40 bar (measuring chamber □ 86)
  • Scale:

    • Uniform scale
    • Double Rock
    • a specific scale (e.g. linear pressure or square root increase)
  • zero point setting:

    • External setting for liquid-filled instruments
    • Adjustable pointer setting for instruments without liquid refill
  • pressure limit (static):

    • Continuous: full scale value
    • Niha: 0.9 x total scale value
  • overload protection and maximum working pressure (static): both sides max 40, 100, 250 or 400 bar
  • location of the link:
    • Bottom bracket (radial)
    • Other connection location on request
  • Process connector:

    • 2 x G ½ female thread
    • 2 x G ½ B male thread
    • 2 x ½ NPT male thread
  • permissible temperature

    • Surrounding area:
      • -20 °C … + 60 °C
      • -40 °C … +60 °C for silicone oil filled versions
    • Medium:
      • ≤ 100 °C
      • > 100 °C
  • Temperature effect: when the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ± 0.5 % / 10 K of the total scale value
  • Transfer fluid in the measuring chamber:

    • Silicone oil
    • Glycerol
    • Other portable liquids on request
  • wetted materials:

    • media chambers with process connection: stainless steel 1.4571
    • pressure element:
      • Monel 2.4360
      • Hastelloy C276 for NACE MR 0175/ISO 15156-T3 design
    • venting of media chambers: the Monel 2.4360
    • Seals: FPM/FKM
    • mouth flanges: Monel 2.4360
  • non-moistened materials:

    • flange connection screws
    • PN 40 and 100: stainless steel
    • PN 250 and 400: corrosion-protected steel
    • measuring chamber: chrome-plated steel
    • Housing: stainless steel, safety level “S1” according to EN 837: With blowing device
    • movement, stainless steel bayonet ring
    • aluminium dial, white, black
    • the instrument pointer:
      • Model 7×2.14: adjustable cursor, aluminium, black
      • Model 7×3.14: standard cursor, aluminium, black
    • Window: Laminated safety glass
    • Ingress protection according to IEC/EN 60529
      • IP54
      • IP65 for liquid-filled instruments
    • Installation with:
      • Rigid measuring lines
      • Mounting holes on the back of the instrument

 

Areas of use, applications

  • filter control
  • pump monitoring and control
  • level measurement on closed containers
  • for gaseous, liquid, contaminated, viscous and aggressive media
  • for measuring locations with high differential pressure overload and/or high operating pressures (static pressures), also in aggressive environments

 

To view additional options 762 .14 and more technical features, we recommend viewing the attached pdfs. documents under the Documentation section.

ELPRO designation: MAN-762.14

Povpraševanje