WDX-SPS3 JOLA floor electrode

Iskanje

Šifra: WDX-SPS3


Po naročilu. Pošljite povpraševanje.

Delivery time: okvirno 2 tedna

  • design: leak detector with quiescent current / NC (interrupting)
  • Housing: PP and cast resin
  • electrical connection: three-wire connection via 3 x 0.75, 2 m connecting cable
  • temperature range: – 20 °C to + 60 °C
  • response sensitivity: approx. 30 kΩ or approx. 33 μS (conductivity)
za merjenje nivoja tekočin, detekcija uhajanja


Področja:

Description

The WDX-SPS3 JOLA floor electrode signals via an electrode relay the presence of liquid medium due to, for example, a burst pipe. Floor electrodes are designed for use in dry rooms.

WDX-SPS3 with integrated galvanic separation:

  • prevents interconnection of electrode circuits
  • prevents the formation of earth loops when more than one detector is connected to a common power supply circuit.

WDX -… conductive plate electrodes should only be used in normally dry environments. They must be installed on the ground with the sensor side facing down and the cable facing up.

The WDX -… conductive plate electrode is equipped with two separate electrodes in the form of two electrode plates: 1 control electrode and 1 ground electrode. As soon as the conductive liquid creates a conductive path between the two electrode plates, the switching state of the leak detector changes.

Conductive measurement principle

The principle of conductive measurement is used to detect electrically conductive liquids. Not suitable for the detection of electrically non-conductive liquids.

Electrically conductive liquids are usually aqueous solutions of salts, acids or alkalis. In water, the molecules of these substances separate into positive and negative ions, which give the aqueous solution its electrical conductivity. The conductive leak detector detects the presence of an electrically conductive liquid and then sounds an alarm.

The measurement process uses alternating current to ensure accurate response sensitivity and to prevent galvanic processes at the electrodes. The conductive leak detector shall have an integrated electronic evaluation unit with galvanically isolated circuits. This prevents the electrode circuits from interconnecting and forming earth loops if more than one of these leakage detectors is connected.

Reliable detection of liquids with poor electrical conductivity, such as condensate or demineralised water, is ensured by the factory-set sensitivity response of the conductive leak detector.

WDX-SPS3 features

  • design: leak detector with quiescent current / NC (interrupting)
  • electrode plates: 2 316 Ti stainless steel plates, each 24 mm in diameter
  • Housing: PP and cast resin
  • electrical connection: three-wire connection via 3 x 0.75 connecting cable, 2 m long; equipped with halogen connecting cable on request
  • supply voltage: only for connection to extra low voltage SELV or PELV! (see datasheet)
  • Energy consumption: max. 0.5 VA
  • output: PNP transistor output wired via a 2 kΩ … 7,5 kΩ downstream input resistor; wire colour: black
  • short-circuit protection: at transistor output, Ik < 30 mA
  • switching condition without supply voltage: low signal
  • switching capacitor for state detection is not activated: the output of the PNP transistor carries the directional supply voltage = high signal
  • switching capacitor for state detection is activated: the output of the PNP transistor carries the directional supply voltage = low signal
  • cable break control: control of cable breakage due to quiescent current
  • galvanic isolation: only for connection to extremely low voltage SELV or PELV! voltage resistance > 500 V between the capacitor circuit and the supply circuit
  • max. no-load voltage across the sensing capacitors: 5 Veff 600 Hz
  • max. short-circuit current on sensing capacitors: 0.2 mA
  • response sensitivity: approx. 30 kΩ or approx. 33 μS (conductivity)
  • temperature range: – 20 °C to + 60 °C

For more technical information, please refer to the datasheet attached under the Documentation tab.

WDX-SPS3 use case: monitoring false floors in a server room using a cable electrode and a panel electrode in an adjacent room.