IPAQ R530 digital universal 2-wire HART-compatible measuring transducer with INOR wireless communication
V zalogi.
Delivery time: 1-3 days
- Exits: Current 4-20 mA
- Made for difficult working conditions
- Inputs: RTD, TC, mV and Ohm
- Approvals: ATEX, IECEx, cFMus
- High accuracy, long-term stability
- programmability via NFC or ICON-BT
- excellent EMC performance; fully compatible with HART® 7 protocol, also with previous HART® 6 and 5
- easy settings via ConSoft software – readability and configurability even “off-line” (programming without external power supply, USB only)
Description
The IPAQ R530 digital universal 2-wire HART7-compatible measuring transmitter with wireless communication is a modern, HART® temperature transmitter that features accuracy and reliability.
Compatible with RTD, thermocouple, voltage and resistance sensors, the universal transmitter offers high flexibility and versatility.
It is fully compatible with HART®7 and offers diagnostic information such as. Errors or status of the transducer.
The IPAQ R530 supports wireless communication via NFC® (Near-field communication) and Bluetooth®, allowing you to configure and monitor the transducer via your smartphone or tablet. For Bluetooth® communication, the ICON-BT interface must be used.
Technical specifications
- Measuring channels: 1 channel
- Power supply: 8 … 36 V DC
- Exits: Current 4-20 mA
- Inputs: RTD, TC, mV and Ohm
- counter for elapsed operation time
- Fully Universal and linear
- ambient temperature: -40 … +85 °C
- Accuracy: 0.08 % of the measuring range
- High insulation level: -1.500 V AC
- configuration with ConSoft or INOR Connect
- Sensor Connection: 2, 3 or 4-water connector
- Humidity: 0 … 98 % RH (non-condensing)
- Vibration resistant to IEC 60068-2-6, 10 g
- NFC® and Bluetooth Wireless Communication® *
Main features of the IPAQ R530
- Output filter
- Measurements with TC
- 5-Year Warranty
- Easy installation
- Power over the current loop
- accuracy and long-term stability
- Customized Linear and engineering units
- Sensor or system error correction
- Removing the sensor error: NAMUR NE43
- Measurements with RTD and other resistance inputs
- fully compatible with HART® 7 protocol, also with previous HART® 6, 5.
The product is factory-set to input Pt 100, measuring range 0… + 100 º C and Output 4… 20 mA. For other areas, order a configuration or purchase a software package.
We invite you to read the article
INOR transducers for accurate and reliable temperature sensor measurements
* Bluetooth® communication is only possible with the ICON-BT interface.
ELPRO Lepenik offers technical support (TP-1, 30 min) and calibration.