IPAQ R530 digital universal 2-wire HART-compatible measuring transducer with INOR wireless communication

Iskanje

Šifra: IPAQ R530

Cena (z vključenim DDV): 372.10
€ 305.00 + DDV


V zalogi.


Delivery time: 1-3 days

  • Exits: Current 4-20 mA
  • Made for difficult working conditions
  • Inputs: RTD, TC, mV and Ohm
  • Approvals: ATEX, IECEx, cFMus
  • High accuracy, long-term stability
  • programmability via NFC or ICON-BT
  • excellent EMC performance; fully compatible with HART® 7 protocol, also with previous HART® 6 and 5
  • easy settings via ConSoft software – readability and configurability even “off-line” (programming without external power supply, USB only)
INOR

Description

The IPAQ R530 digital universal 2-wire HART7-compatible measuring transmitter with wireless communication is a modern, HART® temperature transmitter that features accuracy and reliability.

Compatible with RTD, thermocouple, voltage and resistance sensors, the universal transmitter offers high flexibility and versatility.

It is fully compatible with HART®7 and offers diagnostic information such as. Errors or status of the transducer.

The IPAQ R530 supports wireless communication via NFC® (Near-field communication) and Bluetooth®, allowing you to configure and monitor the transducer via your smartphone or tablet. For Bluetooth® communication, the ICON-BT interface must be used.

 

Technical specifications

  • Measuring channels: 1 channel
  • Power supply: 8 … 36 V DC
  • Exits: Current 4-20 mA
  • Inputs: RTD, TC, mV and Ohm
  • counter for elapsed operation time
  • Fully Universal and linear
  • ambient temperature: -40 … +85 °C
  • Accuracy: 0.08 % of the measuring range
  • High insulation level: -1.500 V AC
  • configuration with ConSoft or INOR Connect
  • Sensor Connection: 2, 3 or 4-water connector
  • Humidity: 0 … 98 % RH (non-condensing)
  • Vibration resistant to IEC 60068-2-6, 10 g
  • NFC® and Bluetooth Wireless Communication® *

 

Main features of the IPAQ R530

  • Output filter
  • Measurements with TC
  • 5-Year Warranty
  • Easy installation
  • Power over the current loop
  • accuracy and long-term stability
  • Customized Linear and engineering units
  • Sensor or system error correction
  • Removing the sensor error: NAMUR NE43
  • Measurements with RTD and other resistance inputs
  • fully compatible with HART® 7 protocol, also with previous HART® 6, 5.

 

The product is factory-set to input Pt 100, measuring range 0… + 100 º C and Output 4… 20 mA. For other areas, order a configuration or purchase a software package.

 

 

We invite you to read the article

INOR transducers for accurate and reliable temperature sensor measurements

 

* Bluetooth® communication is only possible with the ICON-BT interface.

ELPRO Lepenik offers technical support (TP-1, 30 min) and calibration.

Povpraševanje

    You may also like…