HC100 HygroCal generator/calibrator for relative humidity Michell
Po naročilu. Pošljite povpraševanje.
Delivery time: Approximately 4- 6 weeks
- RV range: 5 … 95% RV
- Accuracy: ±0.8 % RH
- RV stability: ±0.5 %
- RH uniformity: ±0.5 %
- Simultaneous validation of 7 relative humidity sensors
- Intuitive user interface to facilitate sensor automation and validation
Description
The HC100 HygroCal generator/calibrator for relative humidity Michell is a compact, portable system for automatic validation and calibration of relative humidity sensors. With a stable test chamber, it enables rapid performance evaluation of relative humidity sensors over a wide range from 5 to 95% RH. The chamber allows the simultaneous installation and validation of 7 humidity sensors of different diameters. The sensors can be powered directly from the validator and controlled via an intuitive touchscreen user interface.
Its intuitive 4-inch touchscreen and interface allows the probes tested to be fully integrated with the chamber and the user interface (UI), so that up to 7 probes with different diameters and output signals can be powered, monitored and recorded simultaneously by a single stand-alone unit.
The HC100 makes it easy to automate the calibration process and provides a complete record of the output of all sensors tested against a reference instrument. These are displayed in CSV format ready for download to your USB memory device.
In use with hygrometer
Optidew
, the HygroCal100 becomes a powerful portable calibration device. Allows testing in the laboratory or on-site (IN-SITU).
It can be equipped with a high-capacity battery that powers the generator and 7 test sensors for up to 8 hours. The unit can also run from the mains while the battery is charging.
Features of HC100 HygroCal
- automated validation process
- portable and fully self-contained
- only 3.2 kg
- thanks to the integrated battery, validation can be performed without access to services
- automated validation procedures for self-testing of sensors
- an internal calibration correction cycle ensures continued confidence
- the downloaded validation data is transferred directly to the USB stick
- optional reference hygrometer with ”chilled mirror” technology –
Optidew
– allows the validator to be used as a calibrator
Areas of use, applications
- On-site or laboratory validation
- validation of RV sensors in pharmaceutical production plants
- validation of RV sensors in meteorological stations
- validation of RV sensors in food production