HC100 HygroCal generator/calibrator for relative humidity Michell

Iskanje

Šifra: HC100


Po naročilu. Pošljite povpraševanje.

Delivery time: Approximately 4- 6 weeks

  • RV range: 5 … 95% RV
  • Accuracy: ±0.8 % RH
  • RV stability: ±0.5 %
  • RH uniformity: ±0.5 %
  • Simultaneous validation of 7 relative humidity sensors
  • Intuitive user interface to facilitate sensor automation and validation
MICHELL

Description

The HC100 HygroCal generator/calibrator for relative humidity Michell is a compact, portable system for automatic validation and calibration of relative humidity sensors. With a stable test chamber, it enables rapid performance evaluation of relative humidity sensors over a wide range from 5 to 95% RH. The chamber allows the simultaneous installation and validation of 7 humidity sensors of different diameters. The sensors can be powered directly from the validator and controlled via an intuitive touchscreen user interface.

Its intuitive 4-inch touchscreen and interface allows the probes tested to be fully integrated with the chamber and the user interface (UI), so that up to 7 probes with different diameters and output signals can be powered, monitored and recorded simultaneously by a single stand-alone unit.

The HC100 makes it easy to automate the calibration process and provides a complete record of the output of all sensors tested against a reference instrument. These are displayed in CSV format ready for download to your USB memory device.

In use with hygrometer
Optidew
, the HygroCal100 becomes a powerful portable calibration device. Allows testing in the laboratory or on-site (IN-SITU).

It can be equipped with a high-capacity battery that powers the generator and 7 test sensors for up to 8 hours. The unit can also run from the mains while the battery is charging.

 

Features of HC100 HygroCal

  • automated validation process
  • portable and fully self-contained
  • only 3.2 kg
  • thanks to the integrated battery, validation can be performed without access to services
  • automated validation procedures for self-testing of sensors
  • an internal calibration correction cycle ensures continued confidence
  • the downloaded validation data is transferred directly to the USB stick
  • optional reference hygrometer with ”chilled mirror” technology –
    Optidew
    – allows the validator to be used as a calibrator

 

Areas of use, applications

  • On-site or laboratory validation
  • validation of RV sensors in pharmaceutical production plants
  • validation of RV sensors in meteorological stations
  • validation of RV sensors in food production

 

Articles

We suggest you take a look at the article ”World Meteorology Day – Precision Measurements in Meteorology”, ”Solutions for Precision Measurements in Meteorology”.

 

Other designations

HC_100, HC 100, HC-100

Povpraševanje