TSR/1/Ti/Ti level dip switch with titanium rod JOLA

Iskanje

Šifra: TSR/1/Ti/Ti


Po naročilu. Pošljite povpraševanje.

Delivery time: okvirno 2 tedna

  • Switching voltage: between 1 V and 42 V AC/DC
  • Switching current: between 1 mA and 500 mA AC
  • Switching power: max. 20 VA
za merjenje nivoja tekočin, detekcija uhajanja


Področja:

Description

The TSR/1/Ti/Ti level dip switch with titanium JOLA rod is used for automatic level control, level indication, limit/point level detection, as a protection against emptying or as a protection against overfilling of liquids in swimming pools. The level switch is designed for vertical installation. The tube is made of stainless steel, which prolongs its life.

Design and operating principle

TSR dip switches have a tube with reed contacts built in. The float is equipped with a permanent magnet. It moves freely up and down the pipe, activating the reed contacts as it ascends and descends. Note that the reed contacts are not locked, but switch only as long as the magnetic field is applied to them. When the float crosses an up or down contact, the contacts return to their original position. Reed contacts can also be restrained by the use of collars that restrict the movement of the float.

TSR/1/Ti/Ti properties

Technical data TSR/1/TiD/Ti7 TSR/1/TiW/Ti4
material of the rod titanium titanium
diameter of the rod 12 mm 19 or 20 mm
length of the rod optionally up to 3,000 mm optionally up to 6,000 mm
threaded adaptor G1/2 G1
float dimensions titanium, 44.5 mm Ø x 52 mm titanium, 79 mm Ø x 95 mm
float for liquids with density ≥ 0.95 g/cm³ ≥ 0.7 g/cm³
IP degree of protection IP65 IP65
junction box PP, 120 x 80 x 55 mm PP, 120 x 80 x 55 mm
installation method Vertical Vertical
temperature range -20 °C to +100 °C -20 °C to +100 °C
pressure resistance max. 10 bar at +20 °C max. 7 bar at +20 °C
Contact NO, NC or OC max. 4 NO, NC or OC max. 8

More technical information can be found under the Documentation tab in the attached pdf documents.

Examples of TSR/1/Ti/Ti applications

Automatic tank emptying

  • The float rises to the highest level with the fluid and triggers the NO contact, which sets the pump in motion via a sequential cycle. The fluid is pumped out. When the minimum level is reached, the NC contact at the bottom is activated, breaking the series circuit and ending the pump operation.

Automatic tank filling

  • The float drops the liquid to the lowest level and triggers the NO contact, which sets the pump in motion via a sequential circuit. The fluid is then pumped inside. When the maximum level is reached, the upper NC contact is activated, breaking the sequential circuit and ending the pump operation.

Examples of standard use

with 1 float and 1 collar fitted over the upper contact

  • It is advisable to fit an additional collar over the top contact. This allows the contacts to be switched after a circuit failure and avoids the rising fluid leaving the float outside the magnet’s area of influence on the contact. The length of the switch hose shall be such that when the float reaches the lower contact it rests on the retaining washer. The recommended distance between the bottom contact and the end of the switch corresponds to the minimum distance specified in the technical data of each TSR model.

with 2 or more floats and appropriate collars

  • To ensure that you do not retain only the upper and lower contacts after switching on, several floats can be used together with appropriate collars. Please respect the minimum contact spacing for these applications.

 