DP 600 leak tester Wöhler
Po naročilu. Pošljite povpraševanje.
Delivery time: approximately 2-3 weeks
- pressure: measuring range: ±7,000 Pa
- volumetric flow rate (without adapter): measuring range: 0 … 200 Nm³/h
- volumetric flow rate (with adapter 3.0): measuring range: 0 … 10 Nm³/h
- volumetric flow rate (with adapter 0.3): measuring range: 0.10 … 18 NL/min
- Power supply: 110 … 230 V, 50 … 60 Hz
Description
The Wöhler DP 600 leak tester monitors the leak tightness of all exhaust systems listed in EN 1443 by measuring the air flow required to maintain the test pressure level.
TESTING TESTING ALL CLASSES DIMENSIONS AND SYSTEMS FOR DRAIN DIMENSIONS GAS
The Wöhler DP 600 checks the tightness of exhaust ducts and chimneys. In the meter menu the user can choose between different types of installation.
Automatically regulates the pressure required for flue gas systems of the type:
- P1 (drainage channels)
- H1 (combined heat (co-generation, cogeneration) and power plants, high-pressure flues )
- N1 and N2(chimneys)
and automatically determines leakage rates.
A variable mode is also available, which allows the user to select the test pressure and leak/leak rate. In this way, it is possible to implement Tests leak tests of ventilation of ventilation systems or flue gas extractionsystems of type P2 or H2.
All results can be printed with a high-speed thermal printer.
CONFIRMATION OF SUFFICIENT COMBUSTION AIR SUPPLY
The device allows confirm sufficient supply of combustion of combustion air v according to z DVGW 625 (“a simple procedure” and “detailed procedure“) with the necessary differential pressure test( 4 Patest ). No auxiliary measuring instrument is required.
The Wöhler DP 600 simulates the combustion air inlet of a fireplace. When the user enters the capacity of the fireplace, the Wöhler DP 600 will automatically produce adequate volume flow, which is through the chimney, and noted the increase in pressure in the room.
Main features
TESTING
leakage rates up to 200.00 m³/h- EXPANDED AREA PRESSURE – up to ±7. 000 Pa
- PRESET CLASSES TESTIMONIALS – for systems flue systems flue gas systems N, P and H v according to s standard EN 1443
- 4 / 8 Pa-TEST – without auxiliary measuring instrument
VARIABLE
MODE – s free optional border value pressure and leakage
PLAYED
MEMORIAL – For to 100 of measurement records
DIRECTORY
USB – for personal PC
DIRECTORY
I RDA – for printer
Technical features
Pressure
- range: 0… 7000 Pa
- resolution:
- 0.1 Pa(0.0… 900.0 Pa)
- 1 Pa… 900 Pa onwards
- 0.1 Pa(0.0… 900.0 Pa)
- Accuracy: ±0.5 Pa, ±2.5 % of reading
Volumetric Flow without adapter
- range: 0.0… 200.0 Nm³/h
- resolution: 0.1 Nm³/h
- Accuracy: ±2.5 Nm3/h, ±5 % of reading
Volumetric Flow z adapter 3.0
- range: 0.00… 10. 00 Nm³/h
- resolution: 0.01 Nm³/h
- Accuracy: ±0.05 Nm3/h, ±5 % of reading
Volumetric Flow z adapter 0.3
- range: 0.10… 18.00 NL/min (0.006 to 1.080 m3/h)
- resolution: 0.01 NL/min
- Accuracy: ± 0.05 NL/min, ±5 % of reading
General Technical Technical Data
- Power supply: 110… 230 V, 50 to 60 Hz
- operating temperature: 5 °C… 40 °C
- Storage temperature :-20 °C… +50 °C
- Dimensions: 33 x 36 x 15 cm
- weight: 9.2 kg
Software
Use
- leak testing with leak rates up to 200.00 m³/h
- testing tightness all classes chimneys and systems for flue flue gas and chimney systems of flue gases
- testing leak testing systems of flue gas of flue gases v in thermal power plants
- confirmation sufficient supply of combustion of combustion air v according to z list MARKETS G 625
- Check tightness furnaces
- Test tightness is can be also z negative pressure
Interesting fact
TESTING PRESS SYSTEMS EXCEPT GAS SYSTEMS
Heating systems, using low-temperature or condensing technology, cause less and less exhaust gas loss. The reduction in exhaust gas losses is linked to a reduction in exhaust gas temperature. Low flue gas temperatures can mean, the flue gases no longer have enough energy to escape outwards through the chimney or flue pipe.
To ensure the heating system works properly, exhaust gases must be extracted using blowers or fans. This causes excess pressure in the exhaust system. Any leaks in the exhaust pipes would cause toxic flue gases to escape into the indoor air. It is therefore advisable to carry out an exhaust system leak test.
Other designations: DP600, DP_600, DP-600