A 550 flue gas analyser, Wöhler

Iskanje

Šifra: A 550


Po naročilu. Pošljite povpraševanje.

Delivery time: approximately 2-3 weeks

  • Sensors: up to five sensors can be connected
  • possible measurements: o2, COv, CO2NDIR, NOv, soot, liquid gas T, SO2, H2S, diff. pressure
  • operating temperature: 5 … 40 °C
  • Power: 3.7 V battery, 6,700 mAh, via USB
  • Communication: wireless LAN, IR (infrared), USB
  • Battery life: 7 hours
WOEHLER

Description

The A 550 flue gas analyser, Wöhler is a universal portable device for flue gas analysis. Up to 5 sensors can be connected (depending on the measurement quantity), allowing a wide range of combinations and applications.

Benefits

Easy to use

Despite its ability to be implemented in challenging, harsh working conditions and environments, maintains an ease of use comparable to handling a smartphone.

Individual functions can be controlled from a smartphone via a 7-inchcolour touchscreen.

Getting measuring values is easy.

Monitor

The monitor is designed for very good visibility.

The large display, clear layout and graphical presentation of the readings make it easy to read.

Sensors

The analyser can be equipped with z maximum 5 sensors.
The wide variety of sensors makes itsuitable for diverse applications.
O2 and
CO with a range of up to 100,000 ppm
.
There is a choice of sensorsthat measure NO2, SO2, NO,CO2 NDIR andH2S.

Accurate, reliable and stable measurements

The A 550provides measuring results z highest accuracy.
Peltier fridge, powered by batery, provided by accurate readings NOX, SOX, and flexibility bcut mains power.
Only dry flue gases enter the instrumentdue to the filtration process that takes place just downstream of the probe. This method ensures reliable and stable measurements.
The probecan be used formeasurements in environments with temperatures up to1200 °C.

Different types of A 550

The flue gas analyser is available in different models depending on the application and the scope of use.

See the attached documentation for more details.

Main features of the A 550

  • Power: 3.7 V battery, 6,700 mAh, via USB
  • Battery life: 7 hours
  • Storage temperature: -20 … +50 °C
  • operating temperature: 5 … 40 °C
  • weight: 1.250 g
  • Dimensions: 220 x 160 x 55 mm (dimensions do not include sensor)
  • cable length: 3 m

O2

  • display: % Vol. refers to a dry liquid gas
  • Sensor: electrochemical
  • range: 0.0 … 21.0%
  • Accuracy: ± 0.3 % Vol.

CO (COv 100.000 ppm)

  • display: % Vol. refers to a dry liquid gas
  • measuring principle: electrochemical sensor
  • area: 0. … 100,000 Vol.%, resolution: 1 Vol.%
  • Accuracy: ± 100 Vol. % ppm (<1.000 Vol. % ppm), otherwise 10 % of the measurement value; with H2:
    < 5% of the measurement value
  • for more values, see the Documentation

NO in liquid gas

  • display: % Vol. refers to a dry liquid gas
  • measuring principle: electrochemical sensor
  • range: 0 … 1.000 % vol.
  • Accuracy: ± 5 Vol. % (< 100 ppm), otherwise 5 % of the measurement value

NO2

  • display: % Vol. refers to a dry liquid gas
  • measuring principle: electrochemical sensor
  • range: 0 … 1.000 % vol.
  • Accuracy: ± 5 Vol. % (< 100 ppm), otherwise 5 % of the measurement value

SO2

  • display: % Vol. % refers to dry liquid gas
  • measuring principle: electrochemical sensor
  • range: 0 … 5.000 Vol. % ppm
  • Accuracy: ±10 Vol. % (< 200 ppm), otherwise ±5 % of the measurement value

CO2 NDIR

  • display: CO2 concentration
  • measurement principle: NDIR
  • range: 0 … 40 % vol.
  • Accuracy: 0 … 6 Vol. %: ±10 Vol. % ppm; 6 … 40 Vol. %: ± 5 % of the measurement value

H2S

  • display: % Vol. % refers to dry liquid gas
  • measuring principle: electrochemical sensor
  • range: 0 … 350 ppm
  • Accuracy: 0 … 40 ppm: ±12 ppm; 40 … 350 ppm: ±5 % of the measurement value

differential pressure

  • display: Pascal
  • measuring principle: semiconducting membrane
  • area: 0.00 … ± 110. hPa; resolution: 0.1 Pa (< 1.000 Pa), otherwise 1 Pa
  • Accuracy: 0.3 Pa (< 10Pa), otherwise 3% of the measurement value

liquid gas temperature

  • Unit: °C
  • measuring principle: NiCr-Ni thermocouple
  • range: -20.0 °C … 100.0 °C, resolution 0.1 °C
  • accuracy: ± 1°C

*all values given are general descriptions and depend on the analyser

More specifications for A 550 types in the Documentation.

Areas of use, applications

  • indoor flue gas analysis
  • humidity in the wood processing and timber industry

At ELPRO Lepenik we offer
calibration of the flue gas analyser.

Video

Other designations: A550, A-550, A_550