IsoPAQ-641 high performance isolation converter for INOR current and voltage signals

Iskanje

Sale!

Šifra: IsoPAQ-641

Redna cena (z vključenim DDV): 418.46 €

Akcijska cena

Cena (z vključenim DDV): 272.06
€ 223.00 + DDV


V zalogi.


  • the input signal:
    0 … 20 mA, 0 … 10 V, 0 … 5 V
    4 … 20 mA, 2 … 10 V, 1 … 5 V
  • output signal:
    0 … 20 mA, 0 … 10 V, 0 … 5 V
    4 … 20 mA, 2 … 10 V, 1 … 5 V
  • Power supply: 24 V DC voltage range 16.8 V… 31.2 V, approx. 0.7 W
  • operating temperature: -25 °C … +70 °C
  • Accuracy: 0.1 % FS
  • Operating voltage: 600 V AC/DC
INOR

Description

The IsoPAQ-641 high performance isolation converter for INOR current and voltage signals with calibrated range selection is used for isolation and conversion of standard signals.

The input and output range as well as the cutoff frequency of the IsoPAQ-641 can be easily configured using a DIP switch. No additional adjustment is needed due to the calibrated range.

Auxiliary power can be supplied via the terminals or via the optional In-Rail-Bus connector. There is a green LED light on the front of the unit for power monitoring.

 

Main features of IsoPAQ-641

  • calibrated signal adjustment via DIP switch:
    adjustable input and output range via DIP switch – high precision without further adjustments
  • 3-input isolation:
    protection against false measurements due to parasitic voltages or earth loops
  • extremely slim design:
    6
    .2 mm slim housing for easy and economical DIN rail mounting
  • Optional In-Rail-Bus attachment connector:
    allows fast and economical installation
  • Safe isolation according to EN 61140:
    protects service personnel and downstream equipment from unacceptable high voltage
  • Maximum reliability:
    no maintenance costs

 

Technical features

  • input
    resistance: current input ≤ 25 Ω, voltage input ≥ 100 kΩ
    overload: current input < 50 mA, voltage input < 30 V
  • output
    load: output current ≤ 12 V (600 Ω at 20 mA), output voltage ≤ 5 mA (2 kΩ at 10 V)
    linear transmission range: -1 … +110 %
    residual ripple: < 10 mVrms
  • general information
    -3d cutoff frequency: 5 kHz, 100 Hz, 10 Hz
    T99 response time: 150 µs, 7 ms, 70 ms
    Test voltage: 3 kV AC, 50 Hz, 1 min
    protection against electric shock: safe isolation according to EN 61140 with reinforced insulation according to EN 61010-1 up to 300 V AC/DC for overvoltage category II and contamination level 2 between all circuits

 

ELPRO Lepenik offers technical support (TP-1, 30 min) and calibration.